技術(shù)參數(shù)
|
GW4G-40.5
|
GW4G-72.5
|
GW4G-126
|
||||||||||
額定電壓kV
|
40.5
|
72.5
|
126
|
||||||||||
額定電流A
|
630
|
1250
|
1600
|
2000
|
630
|
1250
|
1600
|
2000
|
630
|
1250
|
1600
|
2000
|
|
隔離開關(guān)
|
額定峰值耐受電流kA
|
80,
100
|
80,
100
|
100,
125
|
100,
125
|
80,
100
|
80,
100
|
100,
125
|
100,
125
|
80,
100
|
80,
100
|
100,
125
|
100,
125
|
額定短時(shí)耐受電流kA
|
31.5,
40
|
31.5,
40
|
40,
50
|
40,
50
|
31.5,
40
|
31.5,
40
|
40,
50
|
40,
50
|
31.5,
40
|
31.5,
40
|
40,
50
|
40,
50
|
|
額定短路持續(xù)時(shí)間s
|
31.5kA、40kA為4s, 50kA為3s
|
||||||||||||
接地開關(guān)
|
額定峰值耐受電流kA
|
100,125
|
|||||||||||
額定短時(shí)耐受電流kA
|
40,50
|
||||||||||||
額定短路持續(xù)時(shí)間s
|
4,3
|
||||||||||||
額定短時(shí)工頻耐受電壓(有效值)kV
(有效值)kV
|
對(duì)地
|
95/107*
|
160/181*
|
230/260*
|
|||||||||
斷口
|
118/134*
|
200/226*
|
300/340*
|
||||||||||
額定雷電沖擊耐受電壓(峰值)kV
|
對(duì)地
|
185/210*
|
350/396*
|
550/625*
|
|||||||||
斷口
|
215/243*
|
410/464*
|
650/740*
|
||||||||||
所附接地刀與對(duì)面隔離開關(guān)帶電部分暫時(shí)接近過程中最小間隙下1min工頻耐受電壓(kV)
|
——
|
84/95*
|
142/165*
|
||||||||||
額定端子靜態(tài)機(jī)械負(fù)荷N
|
水平縱向
|
1000
|
1000
|
1250
|
|||||||||
水平橫向
|
750
|
750
|
750
|
||||||||||
垂直力
|
1000
|
1000
|
1000
|
||||||||||
無線電干擾水平
|
不大于500μV
|
||||||||||||
開合母線轉(zhuǎn)換電流(母線轉(zhuǎn)換電壓100V)A
|
504
|
1000
|
1280
|
1600
|
504
|
1000
|
1280
|
1600
|
504
|
1000
|
1280
|
1600
|
|
開合電容電流(相電壓)A
|
1,2
|
||||||||||||
開合電感電流(相電壓)A
|
0.5,1
|
||||||||||||
單極重量kg
|
180
|
210
|
260
|
||||||||||
機(jī)械壽命
|
3000次
|